Human TSG101 ELISA Kit
SKU: 46584601542

Human TSG101 ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 8 - Jul 13

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Human TSG101 ELISA KitProduct Specification Usage Experimental equipment required for the experiment: 1. Microplate reader (450nm) 2. High precision pipette and gun tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37 constant temperature box 4. Distilled water or deionized water Sample processing and requirements: Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4 overnight, then centrifuge at 1000g for 20

Product Specification

Usage Experimental equipment required for the experiment:
1. Microplate reader (450nm)

2. High-precision pipette and gun tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL

3. 37℃ constant temperature box

4. Distilled water or deionized water

Sample processing and requirements:
Serum: Place the whole blood sample collected in the serum separation tube at room temperature for 2 hours or at 4℃ overnight, then centrifuge at 1000×g for 20 minutes, and take the supernatant, or store the supernatant at -20℃ or -80℃, but avoid repeated freezing and thawing.

Plasma: Collect the specimen using EDTA or heparin as an anticoagulant. Centrifuge the specimen at 1000 × g for 15 minutes at 2-8°C within 30 minutes of collection. The supernatant can be assayed or stored at -20°C or -80°C, but avoid repeated freezing and thawing.

Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh the tissue and mince it. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1 g of tissue sample to 9 mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed. Finally, centrifuge the homogenate at 5000 × g for 5-10 minutes, and the supernatant can be assayed.

Cell Lysis Buffer: Gently wash adherent cells with ice-cold PBS, then trypsinize and collect cells by centrifugation at 1000×g for 5 minutes. Suspension cells can be collected directly by centrifugation. Wash collected cells three times with ice-cold PBS and resuspend in 150-200 μL of PBS per 1×10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately). Disrupt the cells by repeated freeze-thaw cycles or sonication. Centrifuge the extract at 1500×g for 10 minutes at 2-8°C, and remove the supernatant for analysis.

Cell Culture Supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for analysis or store at -20°C or -80°C, avoiding repeated freeze-thaw cycles.

Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test.

Pre-test preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.

2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL. Serial dilution method: Take 7 EP tubes and add 500 μL of universal diluent to each tube. Pipette 500 μL of the 20 ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10 ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves directly as a blank well; there is no need to aspirate the liquid from the penultimate tube. See the figure below for details.

3. Preparation of Biotinylated Antibody Working Solution: 15 minutes before use, centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration using universal diluent (e.g., 10µL concentrate + 990µL universal diluent). Prepare immediately before use.

4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately.

5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C.

2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.)

3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes.

4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used).

5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes.

6. Washing: Discard the liquid and wash the plate five times as in step 4.

7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.

8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.

2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a capture antibody against Tumor Susceptibility Gene 101 (TSG101). After incubation and washing, the sample is developed using the substrate TMB. TMB is converted to blue by peroxidase (HRP) catalysis and to yellow by acid. The intensity of the color is positively correlated with the amount of Tumor Susceptibility Gene 101 (TSG101) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Human
Synonym Human Tumor Susceptibility Gene 101  ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Tumor susceptibility gene 101, also known as TSG101, encodes a cellular protein of the same name. The protein encoded by this gene belongs to a group of apparently inactive ubiquitin-conjugating enzyme homologs. The gene product contains a coiled-coil domain that interacts with stathmin, a cytosolic phosphoprotein implicated in tumorigenesis. This protein may play a role in cell growth and differentiation and act as a negative growth regulator. Steady-state expression of this tumor susceptibility gene in vitro appears to be important for maintaining genomic stability and cell cycle regulation. Mutations and alternative splicing of this gene occur frequently in breast cancer, suggesting that defects occur during breast cancer tumorigenesis and/or progression. Its primary role is in the ESCRT pathway, which promotes reverse topological budding and the formation of multivesicular bodies (MVBs), which deliver cargo destined for degradation to lysosomes.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.312-20 ng/mL
Applications Serum, plasma, tissue homogenate, cell lysate, cell culture supernatant and other biological fluids
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 46584601542

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.3 ★★★★★
Based on 1636 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
M
Verified Purchase
Mike
Natrona Heights, US
★★★★★ 5
Good product at a great price
Size: 26+17+12.01, Style: 3 piece
I was looking for some wipers that were just like the ones that come on my 2024 Honda HRV and these came up on the Amazon website so I ordered them and the very next day they were delivered to my house!!!!! WOW and they are just like the ones that came on my HRV. Very easy to install with NO adapters to use or parts to take off. All I had to do was take my old wipers off and put on the NEW ones and the price is great too. Also they come well packaged and a plastic guard is over the rubber for more protection in the shipping so be sure to take that off before install, you’d be surprised how many people would leave it on and think that they don’t work properly. Note: Be sure to clean your windshield before you use your wipers cause road scum or wax from car washes will make you think that they don’t work. I had some problems but once I cleaned my windshield really good there was no streaks at all. Now I don’t know how long they will last cause I just got them, may do another review in the future.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on November 17, 2025
S
Verified Purchase
STEVEN V RENZULLI
Omaha, US
★★★★★ 5
Great value and sturdy product
Size: 22+22, Style: 2 piece
Fit perfectly, and for the first time installation of wiper blades formed was a breeze! Great value and delivered when promised.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 12, 2026
L
Verified Purchase
Leo Madrid,aka Marciano
Boise, US
★★★★★ 5
Very impressed nice blades do the job!!!
Size: 26+16+12, Style: 3 piece
Very nice windshield wipers very clean and no smuges !!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 15, 2026
D
Verified Purchase
Dude
Battle Creek, US
★★★★★ 4
Two out of three
Size: 26+18+12, Style: 3 piece
Did not fit the rear wiper on a 2023 QX50 Signature. It has a different carrier than the old one. Front ones went right on and work well.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 29, 2026
A
Verified Purchase
A_CPA
Massapequa, US
★★★★★ 5
Two Filters, Quick and Easy
Size: 16-23 Tacoma, Size: 16-23 Tacoma
The RVgolf Engine+Cabin Air Filters Kit for the Toyota Tacoma V6 comes with two air filters. There is a cabin air filter that fits nicely into the compartment accessed through the glove box and an engine air filter that dropped in easily in the compartment under the hood. Replacement of both filters was easy, didn’t require any tools, and it took more time to empty and replace the items in the glove box than it did to replace both filters. The Toyota dealership quoted me $80 to replace the cabin air filter only. I replaced both filters for less than $30. The filters felt like they were good quality. The engine air filter is multi-layered, with a thin foam layer to keep larger debris from blocking the finer paper filter. The cabin air filter said and looked like it had a carbon layer to absorb smells. The only concern I had was size. After I had replaced both filters I went to slide the engine air filter I replaced into the RVgolf box to throw it away. The engine air filter I replaced would not slide into the RVgolf box. It was too big. After driving for a few days and a couple of hundred miles, I popped the hood and checked the fit of the engine air filter. The fit looked perfect. See attached photos.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 9, 2026

recommand products